Cold Rooms


Technical Specifications


Dimensions 3.8m * 2.8m * 2.5m
Walls & Ceiling Constructed form panel; inner layer of anti-bacteria and anti-rust SS304 (0.5mm) and outer layer of anti-rust and anti-bacteria galvanized sheet (0.6mm) infused with polyurethane (40Kg/mm³)
Total Thickness: 10cm equipped with dividers for expansion or transport.
Flooring Constructed form panel; inner layer of anti-bacteria and anti-rust SS304 (0.5mm) and outer layer of anti-rust and anti-bacteria galvanized sheet infused (0.6mm) with polyurethane (40Kg/mm³)
Easily Cleanable with no possibility of dust accumulation with the addition of insulating materials to the bottom of the flooring to ensure that it won't be affected by moisture.
Doors Constucted from same materials as walls
Tightly sealed
Automatically closes when left open and can be opened internally
Lock and key & equipped with security system.
Interior SS304 shelves. Distance between floor and first shelf: 200mm. Shelf load of 1Kg/cm². Distance between shelf bearers: 1m
Shelf depth: 600mm. Vertical space between shelves: 400mm.
Room equipped with a non-compressive valve.
In case of power outage, the room maintains a temperature not exceeding 10° for 8 hours.
Interior Lighting LED bulbs
Vertical Light Intensity: 250lux (can be increased)
Cooling System Chiller (Water)
2 4-horsepower Carrier chiller units that work interchangeably
365 days full-energy operation
European Components
Composed of:
Condenser, Cooling Fan, Angle Valve, Drain Filter, Expansion Valve, Automatic Water Make uo, High Pressure Switch, Low Pressure Switch, Oil Solonit Bitzer, Oil Solonit Valve, Evaporator, Bypass Valve (Requlating Valve), Pump, Cooling Water Return, Cooling Water Outlet
Alarm System Integrated intelligent system monitors the temperature of the room 24 hours a day, 365 days a year, equipped with a computer and printer for daily or monthly room performance reports, equipped with a calibration program for the internal temperature sensors of the room automatically every 15 minutes, temperature stability report on the system computer and can be preset.
Settable program to set the required temperature with an upper and lower limit for the alarm temperature. The system communicates with all components of the main room to continuously follow the efficiency and operation of components with efficiency reports displayed on the system computer. Warnings provided in the event of a malfunction in either or both of the cooling units or room air distribution units.
Equipped with a separate visual and audible alarm system for power outages through a self-charging system for emergencies.
Electricity Room can be connected to 220V : 240V electrical generators
Electronic control panel for temperature control including protection units against fluctuating electric current and high pressures